Original Research Article | OPEN ACCESS

New highly-sensitive ultra-performance liquid chromatography - mass spectrometry method for quantification of telmisartan in human plasma

Tanveer A Wani1 , Seema Zargar2

1Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, PO Box 2457, Riyadh 11451; 2Department of Biochemistry, College of Science, King Saud University, PO Box 22452, Riyadh 11211, Saudi Arabia.

For correspondence:-    

Received: 1 November 2014        Accepted: 20 February 2015        Published: 31 March 2015

Citation: Wani TA, Zargar S. New highly-sensitive ultra-performance liquid chromatography - mass spectrometry method for quantification of telmisartan in human plasma. Trop J Pharm Res 2015; 14(3):511-518 doi: 10.4314/tjpr.v14i3.21

© 2015 The authors.
This is an Open Access article that uses a funding model which does not charge readers or their institutions for access and distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) and the Budapest Open Access Initiative (http://www.budapestopenaccessinitiative.org/read), which permit unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited..

Abstract

Purpose: To develop and validate a simple, rapid, sensitive and specific ultraperformance liquid chromatography mass spectrometry method for the quantification of the angiotensin II receptor antagonist, telmisartan (TEL), in human plasma.
Methods: After simple protein precipitation using acetonitrile and methanol, TEL and internal standard (IS) abiraterone were separated on Acquity UPLC BEHTM C18 column (50 x 2.1 mm, i.d. 1.7 µm, Waters, USA) using a mobile phase consisting of acetonitrile: 8 mM ammonium acetate containing 0.15 % formic acid (v/v) (70:30) pumped at a flow rate of 0.3 mL/min and detected by tandem mass spectrometry with positive ion mode. The ion transitions recorded in multiple reaction monitoring mode were m/z 515.27→276.13 for telmisartan and m/z 350.1 > 156.0 for internal standard, abiraterone.
Results: The assay exhibited a linear dynamic range of 1 – 200 ng/mL for telmisartan in human plasma with good correlation coefficient (0.995) and limit of quantitation of 1 ng/mL. The relative standard deviation for the intra- and inter-assay precision was between 0.75-11.50
Conclusion: The developed UPLC-MS/MS method is simple, rapid and highly sensitive, and should thus be suitable for pharmacokinetic and toxicokinetic studies in both animals and humans.

Keywords: Telmisartan, Ultra-Performance liquid chromatography, Tandem mass spectrometry, Pharmacokinetics, Toxicokinetics, High throughput analysis

Impact Factor
Thompson Reuters (ISI): 0.523 (2021)
H-5 index (Google Scholar): 39 (2021)

Article Tools

Share this article with



Article status: Free
Fulltext in PDF
Similar articles in Google
Similar article in this Journal:

Archives

2024; 23: 
1,   2,   3,   4
2023; 22: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2022; 21: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2021; 20: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2020; 19: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2019; 18: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2018; 17: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2017; 16: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2016; 15: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2015; 14: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2014; 13: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2013; 12: 
1,   2,   3,   4,   5,   6
2012; 11: 
1,   2,   3,   4,   5,   6
2011; 10: 
1,   2,   3,   4,   5,   6
2010; 9: 
1,   2,   3,   4,   5,   6
2009; 8: 
1,   2,   3,   4,   5,   6
2008; 7: 
1,   2,   3,   4
2007; 6: 
1,   2,   3,   4
2006; 5: 
1,   2
2005; 4: 
1,   2
2004; 3: 
1
2003; 2: 
1,   2
2002; 1: 
1,   2

News Updates